Bioequivalence, population bioequivalence and in-vitro statistics
In bioequivalence and in-vitro work, the statistical method often decides the conclusion. We design and analyse these studies with the method rationale reviewers look for, under FDA, EMA, MHRA and other agencies’ guidance, and we explain the choice in the report.
Bioequivalence statistical analysis
Design, sample size and analysis for crossover, parallel and replicate designs, including reference-scaled average bioequivalence for highly variable drugs and studies with interim analyses. Non-compartmental pharmacokinetic analysis and PK/PD support.
We also review pilot study results to inform the design of the pivotal study.
Population bioequivalence (PBE)
PBE analyses following the relevant FDA product-specific guidance, for example for particle size distribution comparisons. We can also help your team build and document its own PBE analysis capability.
Dissolution profile comparison: f2 and bootstrap f2
Similarity assessments for biowaivers and post-approval changes, using the approach the data and the guidance support:
- f2 similarity factor, when the variability conditions for its use are met
- Bootstrap 90% confidence interval of the expected f2 (f2,EXP), when variability is too high for the conventional f2
- Multivariate statistical distance (MSD), model-independent, as a supporting analysis where justified
- Model-dependent approaches (for example Weibull, logistic, probit), as supporting analyses where justified
Every report states why the chosen method is appropriate.
For EU submissions, EMA’s questions and answers describe the bootstrap confidence interval for f2 as the preferred approach when the conventional f2 is not suitable. They state that the Mahalanobis distance cannot be supported as a preferred approach, and that a confidence region of a multivariate distance of Weibull model parameters was not considered adequate. We choose and justify the method with this in mind.
Source: EMA, ‘Clinical pharmacology and pharmacokinetics: questions and answers’, Q&A 3.13 ‘MWP Q&A on In Vitro Dissolution Profile Comparison for Bioequivalence Inference’ (with Q&As 3.9 and 3.11): https://www.ema.europa.eu/en/scientific-guidelines/clinical-pharmacology-pharmacokinetics-questions-answers#3.-bioequivalence-(general)-section
How we run bootstrap f2
We estimate the two-sided 90% confidence interval of the expected f2 (f2,EXP) by bootstrapping, using at least 5,000 bootstrap samples and a percentile method, following the methodology described in EMA’s Q&A 3.13. Similarity is concluded when the lower limit of the interval is 50 or above. The report sets out the software, the number of bootstrap samples, the seed and the interval method, so the conclusion can be reviewed and reproduced.
Earth Mover’s Distance (EMD)
EMD measures how far apart two whole distributions are, rather than comparing a few summary values. We use it to compare test and reference distributions, such as particle size distributions, where the applicable product-specific guidance supports this approach.
IVRT statistics
Statistical design and analysis of in-vitro release testing studies comparing the release rates of test and reference semi-solid products, including the equivalence assessment and a report that documents the method and its justification.
IVPT statistics
Statistical design and analysis of in-vitro permeation testing studies for topical and transdermal products: accounting for donor-to-donor variability, comparing permeation parameters between test and reference, and documenting the method in line with the applicable guidance.
IVIVR and convolution modelling
Models that relate in-vitro dissolution to in-vivo pharmacokinetics, to inform formulation decisions before in-vivo studies and to support the evaluation of formulation changes.
BIMO listings
Bioresearch monitoring (BIMO) listings for BA/BE and clinical submissions to US FDA, programmed in R and checked alongside the study datasets.
Analytical and stability statistics
Method validation statistics in line with ICH Q2(R2) principles, trend analysis, stability data evaluation, equivalence and comparability assessments, and k-factor calculations.
Review of failed or borderline studies
Independent statistical review of a failed or borderline BE or in-vitro study, to find the design, method or data issue before you run the next one.
Tools behind this work
PS-Disso (dissolution similarity) and PS-AVTAR (BA/BE analysis) make routine analyses faster and repeatable. When we run the analysis, our statisticians review the results before they are reported. Both tools are also available to license.
Frequently asked questions
When should bootstrap f2 be used instead of the conventional f2?
Under EMA's Q&A 3.13, when variability in either product exceeds 20% at sampling times in the first 10 minutes or 10% at later times. The recommended approach is the two-sided 90% confidence interval of the expected f2 from at least 5,000 bootstrap samples; similarity is concluded when the lower limit is 50 or above.
Does EMA accept the Mahalanobis distance for dissolution similarity?
EMA's Q&A 3.9 states that the Mahalanobis distance cannot be supported as a preferred approach, even where f2 should not be used. We use MSD only as a supporting analysis, where it is justified.
Can you run population bioequivalence analyses for FDA?
Yes. We analyse PBE following the relevant FDA product-specific guidance, for example for particle size distribution comparisons.
Do you analyse IVRT and IVPT studies for topical generics?
Yes. We design and analyse IVRT and IVPT studies, including the test-versus-reference comparison and a report that documents the method.
Can you prepare BIMO listings for an FDA bioequivalence submission?
Yes. We program BIMO listings in R and check them against the study datasets.
Facing a similarity or bioequivalence question?
Tell us the product, the design and the agency. A senior statistician reads every enquiry.
